Send Message
Home ProductsAir Cooled Modular Chiller

R410A 460kW Residential Air Handling Unit Multi Grade Modulation

R410A 460kW Residential Air Handling Unit Multi Grade Modulation

  • R410A 460kW Residential Air Handling Unit Multi Grade Modulation
  • R410A 460kW Residential Air Handling Unit Multi Grade Modulation
  • R410A 460kW Residential Air Handling Unit Multi Grade Modulation
R410A 460kW Residential Air Handling Unit Multi Grade Modulation
Product Details:
Place of Origin: China
Brand Name: EuroKlimat
Certification: ISO9001, ISO14001, OHSAS18001, CRAA, CQC
Model Number: EKAC1600CR1
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: USD 200 per ton
Packaging Details: Plywood
Delivery Time: 30 working days after received your payment
Payment Terms: L/C, T/T
Supply Ability: 1,000 pcs per month
Contact Now
Detailed Product Description
Cooling Capacity: 460 KW Heat Capacity: 470 KW
Evaporator Type: Shell Tube Weight: 3360 Kg
Dimension(l*w*h): 4630mm*2265mm*2425mm Refrigerant: R410A
High Light:

R410A Residential Air Handling Unit

,

Residential Air Handling Unit

,

460kW Indoor Air Handling Unit

460kW air cooled scroll chiller

 

Features

 

  • Overview

EKAC series air-cooled chiller (heat pump) units are highly reliable, secure and flexible.

This series of units are elaborately designed to be delicate and elegant. In addition, they can support fan coils and air handling units of various specifications and models.

 

Units of this series are marked for their high efficiency, low noise, user-friendliness, secure operation, easy installation and maintenance etc, and are widely used in factories, stations, hotels, villas, office buildings, top-grade residences etc. Besides, they can also be used in industrial chilling.

 

  • Multi-grade Modulation

EKAC1600 series units feature 4-grade modulation which can be transformed to multi-grade modulations in modular combinations. For example, 16 EKAC1600 units can realize 16 modulation grades with effects very similar to that of stepless modulation. With operation grades controlled electronically, the unit exerts less shock to the power grid and saves more energy.

 

  • Outstanding Performance

EKAC series units feature leading-edge technologies and name-brand accessories which are strictly tested for compatibility. Fully hermetic volute compressor and low-noise fans minimize the operation noise. With efficient volute compressors and precise throttling systems with electronic expansion valves, the units feature high EER and COP, especially at partial workload.

 

  • Easy Control

Units can be controlled individually or together by an electronic controller. The controller is strongly interference proof and can exert control from as far as 1000 meters away. Failures are indicated by error codes displayed on the controller to facilitate troubleshooting.

 

  • Easy Installation

The units are designed to best facilitate installation. The cooling system is made hermetic in the factory. Customers do not need to connect any copper pipe or refill refrigerant. The water system has an inlet connector which is to be connected to the terminal equipment. Having installed the unit as instructed, customers just need to check that water and pump pipes are clean before pumping water and powering on the unit.

 

  • Defrosting

The controller defrosts the unit automatically according to the operation time of the unit and the temperature of the heat exchanger.

 

 

 

  • Safety Measures

The cooling system is protected against extreme pressures: discharge pressure will not be too high, nor will inhaling pressure be too low; against extreme discharge temperature: discharge temperature will not be too high; against freezing during cooling operation: when the water temperature is too low, the plate heat exchanger will not freeze up or burst internally; and against low temperature: during cold winter time, the water pipe and plate heat exchanger will not freeze up or burst internally (This feature works only when the system is working in the heating mode with the main power supply turned on).

 

  • Highly Adaptive

The unit shell is made of galvanized, phosphorized steel plate with pure polyester plating to withstand weathering. The unit is reasonably designed to save space. It can be mounted on walls, balconies or the roof, thus eliminating the need for a dedicated equipment room.

The unit is highly adaptive and can operate smoothly in hostile conditions such as extremely high or low temperatures.

 

  • Easy Maintenance

To access and service any part of the unit, you just need to dismantle the side panel or the front panel. When the unit stops working abnormally, the controller prompts the reason to facilitate troubleshooting.


Specifications:

 

Model     EKAC1600C1M EKAC1600CR1M
Nominal cooling capacity   kW 460 460
Nominal heating capacity   kW - 470
Total power of nominal cooling capacity   kW 138 138
Total power of nominal Heating capacity   kW -  
Nominal cooling operation current   A    
Nominal heating operation current   A -  
                 EER COP 3.33 3.33
Power supply     380V/3N~/50Hz
Refrigerant Type     R410A
Refrigerant Control     Electronic Expansion Valve
Compressor Type   Scroll
Qty Nr 4 4
Model   CH485 CH485
Brand   DANFOSS DANFOSS
Lubricant   POE
Water side heat exchanger Type   Efficient shell tube heat exchanger
Water Flow Cooling m³/h 79.1 79.1
Water Flow Heating m³/h -  
Water resistance kPa    
Pipe Min.size of inlet/outlet water pipe connector   DN125
Recommended length of inlet/outlet water pipe inch depend on water pump
Fan Condenser Type   Axial Fan
Qty Nr 8 8
Unit Length mm 4630 4630
Width mm 2265 2265
Height mm 2425 2425
Net Weight Kg 3340 3360

 

 

Note:

1. Working conditions for nominal cooling capacity: outlet water temperature 7°C; water flow: 0.172m³/(h·kW); outdoor ambient temperature 35°C.

2. Working conditions for nominal heating capacity: outlet water temperature 45°C; water flow: 0.172 m³/(h·kW); outdoor dry / web bulb temperature 7°C / 6°C.

  3. Water resistance excludes water pressure drop of the unit and the attached Y-shaped filter;

      4. A maximum of 16 units can be connected to form a modular combination.

      5. Specifications are subject to change due to design variations without further notice.

Contact Details
Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd

Contact Person: Mr. LENG Zhengliang

Tel: +86 13828797702

Fax: 86-0769-83622528

Send your inquiry directly to us (0 / 3000)