Home ProductsVRF Air Conditioner

Household 2 Ton / 3 Ton Heat Pump Package Unit HVAC Air Conditioning

Household 2 Ton / 3 Ton Heat Pump Package Unit HVAC Air Conditioning

    • Household 2 Ton / 3 Ton Heat Pump Package Unit HVAC Air Conditioning
    • Household 2 Ton / 3 Ton Heat Pump Package Unit HVAC Air Conditioning
  • Household 2 Ton / 3 Ton Heat Pump Package Unit HVAC Air Conditioning

    Product Details:

    Place of Origin: China
    Brand Name: EuroKlimat
    Certification: ISO9001, ISO14001, OHSAS18001, CRAA, CQC
    Model Number: EKRV-B

    Payment & Shipping Terms:

    Minimum Order Quantity: 1pcs
    Price: Negotiation
    Packaging Details: Pallet
    Delivery Time: 4weeks after received your payment
    Payment Terms: L/C, T/T
    Supply Ability: 2000pcs per month
    Contact Now
    Detailed Product Description
    Product Name: EKRV-B Series Friendly Refrigerant Inverter Multi-connected Household Central Air-conditioning Cooling Capacity(kW): 10.0kW-18.0kW
    Heating Capacity(kW): 12kW-20.0kW Refrigerant Type: R410A
    Range Of Sound Level DB(A): 54-57

     

    EKRV-B Series Inverter Multi-connected Household Central Air-conditioning

     

    Parameter

     

    Model   EKRV035BR1 EKRV040BR1 EKRV050BR1 EKRV060BR1 EKRV070BR1
    Power supply   220V~/50Hz 380V/3N~/50HZ
    Rated cooling capacity kW 10 12 14 16 18
    Rated heating capacity kW 12 14 16 18 20
    Rated cooling input power kW 2.63 3.2 3.88 4.54 5.21
    Rated heating input power kW 2.85 3.29 3.92 4.65 5.29
    Rated cooling input current A 12 14.5 17.6 20.6 9.9
    Rated heating input current A 13 15 17.8 21.1 10
    External dimensions (W×D×H) mm 900×350×1030 900×350×1030 900×350×1160 900×350×1290 900×350×1420
    Weight of the unit Kg 105 105 120 135 150
    Operating noise dB(A) 54 54 55 56 57
    Piping Liquid pipe mm(in) Ф9.52
    Air pipe mm(in) Ф15.88 Ф19.05
    Pipe connection mode   Evase connected to the threaded joint
    Refrigerant   R410A
    Maximum number of connected indoor units Set 7 8 10 11 13

     

     

    Description:

     

    Super High Air Supply Temperature in Low Temperature Environment
    Scroll compressor enjoys a wider working temperature range than rotor compressor. Enhanced vapor injection can break through the limit of exhaust pressure and exhaust temperature in low temperature environment, to substantially increase the unit's heating capacity and the air supply temperature indoors.
    When the ambient temperature is -25ºC, the maximum air supply temperature of EK inverter multi-connected indoor units can reach 41ºC.

     

    Technology of Heating in Low Temperature Environment
    With enhanced compressor frequency and the EVI function, the attenuation of heating capacity for EKRV-B series inverter multi-connected units under -15ºC ambient temperature is almost 0, which perfectly resolve the heating issue in cold areas in winters.

     

    Lower Noise from Scroll Compressor
    All series units adopt scroll DC inverter compressor. Compared with the common rotor inverter compressor, it features a more stable operating, less vibration, lower noise, and higher energy efficiency and longer life span.

     

    Integrated Intelligent Temperature Control Technology
    Quality temperature sensor can precisely detect the air supply temperature, air return temperature and indoor temperature. The indoor unit's control chip can intelligently sensor the change in temperature, and then automatically adjust the actual cooling capacity or heating capacity of the indoor unit to keep constant indoor temperature with a tiny variation of ±0.5ºC.

     

    Broad Working Temperature Range
    Advanced cooling system enables reliable running of EKRV-B series units. A cozy indoor environment is guaranteed, no matter in a summer when the outdoor temperature is 48ºC or in a winter when it is -30ºC.
    Range of cooling operating temperature: 5~48ºC
    Range of heating operating temperature: -30~29ºC

     

    Exquisite Design, Pipe Connection From Three Sides
    The clever design of unit enabled the refrigerant pipe to be directed out from the front side, rear side, or bottom of the unit. This is space-saving and facilitates the on-site construction.

     

    Long Pipe and Large Elevation Difference

    Item 3.5HP/4HP/5HP 6HP/7HP
    Maximum equivalent pipe length (m) 50 70
    Maximum elevation difference between
    outdoor unit and indoor unit (m)
    20 30
    Maximum elevation difference between
    indoor units (m)
    15 15
    Length from the first branch pipe to the
    farthest indoor unit (m)
    25 30
    Note: All pipe lengths here are equivalent lengths.    

     

    Remote Monitor (Optional)
    Remote intelligent control over smart phone/laptop
    Intelligent software in cell phone can be used to implement remote monitor and control over air-conditioning units. Comprehensive and dynamic monitor of the running status of indoor and outdoor units make the life easier.
    Centralized monitor through computer
    Centralized monitor software for EK multi-connected units can perform centralized control of a maximum of 32 outdoor units.

     

    Non-polar Communication
    Advanced non-polar communication processing is adopted by connecting outdoor and indoor units with non-polar communication cables. This can prevent communication failure caused by incorrect cabling over communication ports during on-site construction.

     

    Applications

    hotels,entertainment centers, hospitals, restaurants, office buildings, cinemas,

    factories, school supermarkets and so on.

    Competitive Advantage:

    EKRV unit using R410A refrigerant meets the energy saving and environmental protection.

    Contact Details
    Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd

    Contact Person: LENG

    Send your inquiry directly to us (0 / 3000)

    Other Products