Home ProductsSplit Air Conditioning Units

Industrial Smart Control Split Air Conditioning Units Low Noise

Industrial Smart Control Split Air Conditioning Units Low Noise

    • Industrial Smart Control Split Air Conditioning Units Low Noise
    • Industrial Smart Control Split Air Conditioning Units Low Noise
  • Industrial Smart Control Split Air Conditioning Units Low Noise

    Product Details:

    Place of Origin: China
    Brand Name: Euroklimat
    Certification: ISO9001, ISO14001, OHSAS18001, CRAA, CQC
    Model Number: EKDB 125A(R) - EKDB 200A(R)

    Payment & Shipping Terms:

    Minimum Order Quantity: 1pcs
    Price: negotiation
    Packaging Details: Packed in carton firstly,and then reinforced with wooden case for outer packing
    Delivery Time: 10 working days after received your payment
    Payment Terms: T/T or western Union
    Supply Ability: 3,000pcs per month
    Contact Now
    Detailed Product Description
    Product Name: EKDB 125A(R) - EKDB 200A(R) Air Flow Range: 6500~10800 M3/h
    Cooling Capactiyt Range: 30 KW~50 KW Heating Capacity Range: 32.5 KW~56 KW

    EKDB 125A(R) - EKDB 200A(R)   high static pressure duct type air conditioning unit

     

     

    Specifications:

     

    Unit model Indoor unit EKDB
    125A
    EKDB
    125AR
    EKDB
    150A
    EKDB
    150AR
    EKDB
    200A
    EKDB
    200AR
    Outdoor unit EKAA
    125AB
    EKAA
    125ARB
    EKAA
    150AB
    EKAA
    150ARB
    2xEKAA
    100AB
    2xEKAA
    100ARB
    Nominal cooling capacity W 30000 30000 40000 40000 50000 50000
    Nominal heating capacity W -- 32500 -- 46000 -- 56000
    Indoor unit Air flow m3/h 6500   7800 10800
    External static pressure Pa 150   150 150
    Fan drive mode   V-belt transmission
    Width x depth x height mm 1719x965x736
    Weight kg 188 188 193
    Outdoor unit Compressor model   Fully hermetic volute
    Width x depth x height mm 990x840x1840 1290x840x1840 2x990x840x1840
    Weight kg 270 285 285 300 2x265 2x280
    Power supply 380V/3N~/50Hz
    Rated input power
    of integrated unit
    Cooling W 12100 12245 16130 17470 20410 20165
    Heating W -- 10000 -- 14700 -- 20300
    Rated current of integrated unit Cooling A 22 22 30 30 37 36
    Heating A -- 20.5 -- 29 -- 39
    Refrigerant Type   R22
    Connection pipe Connect mode   Soldering
    External diameter of liquid tube mm 15.88 15.88 2x15.88
    External diameter of air tube mm 28.6 34.9 2x28.6
    Condensed water drainage pipe   R1
    External electric heater box Model   ACDB-EH6, ACDB-EH8, ACDB-EH10, ACDB-EH12.5, ACDB-EH15, ACDB-EH20, ACDB-EH25, ACDB-EH30, ACDB-EH38, ACDB-EH45, ACDB-EH55
    Description   You can select an external electric heater box according
    to the required heating capacity. For specifications of external electric heater boxes, see P22.

     

    Note:
    ■ The rated cooling capacity is measured in the following condition: The indoor air dry bulb reads 27°C, the wet bulb reads 19°C, and the
    outdoor dry bulb reads 35°C. The condition for the rated heating capacity is as follows: The indoor air dry bulb reads 20°C, the outdoor dry
    bulb reads 7°C, and the wet bulb reads 6°C. The cooling capacity and heating capacity change according to the conditions. During model
    selection, you need to select a proper model based on local climatic conditions.
    ■ External static pressure indicates the static pressure under the nominal air flow. The static pressure may change depending on customer
    requirements. For the specific value, see the reading on the nameplate.
    ■ The unit input power and current are based on the standard external static pressure. If the customer requires a different external static
    pressure, check the nameplate on the unit for the power and current values.
    ■ The specifications may suffer change due to product update. The readings on the nameplate of the unit prevail.
    ■ The preceding data is based on the condition that the connection pipe between indoor and outdoor units is 7.5m.
    ■ For details about on-site power distribution and wiring for unit installation, see the nameplate or installation manual of the unit.
    ■ No refrigerant is filled into any unit upon factory delivery

     

    Description:

     

    1, Outstanding fans, motors and other components specially designed for air conditioners ensure that the unit operates smoothly.

    2, Brand-new dustproof and rustproof painting makes sure that the outdoor unit looks new after many years of operation.

    3, The outdoor unit adopts modular design and stepped startup, efficiently reducing shock on the grid.

    4, Multiple levels of cooling are provided, allowing differential energy regulation under different load conditions and reducing the operating cost.

    5, The compressors support even wear, prolonging the lifecycle

    6, Featuring a high static pressure design, the indoor unit can supply conditioned air over a long distance, enabling customers to select the installation site as required. To service any component of the unit, you only need to remove several screws on either side of the unit.

    7, The connection pipe between indoor and outdoor units reaches up to 50 m, and the height difference can reach 20 m.

    8, The outdoor unit adopts top air supply, allowing combined installation of multiple outdoor units for pleasant appearance.

    9, The indoor unit features an efficient and low-noise centrifugal fan as well as sound-absorbing and thermal insulation inner walls to ensure silent operation.

    10, The indoor unit can be mounted on a far-away ceiling to make the conditioned room more silent.

    11, Unique insulation design for compressors ensures an outstanding insulation performance.

    12, The outdoor unit uses new spiral fans, which have smooth an air suction structure, greatly reduce turbulent flows, and lower the air flow noise.

    13, The smart microcomputer controller supports four operation modes: cooling, heating, fan, and auto control. It also provides timed ON/OFF, auto-defrosting, and fault display functions.

    14, The unit uses a brand efficient volute compressor, which consumes less electricity while providing the same cooling/ heating capacity. The compressor features a small volume and stable running. The unit uses advanced thermal expansion valve control technology to accurately control tributary flows.

    15, During operation, if the power fails, the unit can automatically start once the power resumes no matter how long the power failure lasts. After starting from an exceptional power failure, the unit automatically resumes the running status before the power failure. This function is not enabled upon factory delivery. It needs to be set through DIP switches on site.

    16, The unit has strong adaptability to the environment. It can normally perform cooling when the outdoor temperature is between 18°C and 48°C. It can normally perform heating when the outdoor temperature is between -10°C and 27°C.

    17, The outdoor unit of the low-temperature cooling unit uses a brushless DC motor to control the rotation speed of the condensing fan, efficiently expanding the operating range of the unit and allowing it to normally perform cooling when the outdoor ambient temperature is between -10°C and 48°C.

    18, Multiple types of units with electric heater boxes or hot water coil boxes are available.

    19, The outdoor unit produces a low noise. The system is optimized to suppress vibration and noise during operation, achieving quiet and stable unit running.

    20, The unit normally runs within ±10% of the rated voltage

    21,The shell of the outdoor unit is sprayed with anti-UV and pure polyester mineral highlighter on dual sides, effectively prolonging the lifecycle of the unit.

     

    Applications:

     

    The EKDB high static pressure duct type air conditioning unit meets customer requirements for product efficiency, performance, safety, and intelligence. Flexible combination and intelligent control allow the product to fit into indoor space, bringing customers comfortable experience of a central air conditioner. In addition, a low temperature cooling unit is available. With its efficiency, low noise, delicate structure, easy operation, safe running, and convenient installation and maintenance, it is widely applicable to commercial scenarios such as hotels, malls, office buildings, and factory workshops.

     

    Competitive Advantage:

    1.Outstanding Performance    

    2. Multi-system design (EKDB200~EKDB600) 

    3. Easy Installation              

    4. Silent Operation                       

    5. Smart Control                 

    6. Increasing Efficiency and Saving Energy                  

    7. Power Recovery and Memory Functions        

    8. Wide Application Scope             

    9. Optimized System and Quiet Running         

    10. Wide Voltage Range                  

     11. Multiple Protections              

    12. Dual-sided spraying for long lifecycle

    Industrial Smart Control Split Air Conditioning Units Low Noise

    Contact Details
    Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd

    Contact Person: LENG

    Send your inquiry directly to us (0 / 3000)

    Other Products