    Product Details:

    Place of Origin: China
    Brand Name: Euroklimat
    Certification: ISO9001, ISO14001, OHSAS18001, CRAA, CQC
    Model Number: EKDB 200ARX-300ARX

    Payment & Shipping Terms:

    Minimum Order Quantity: 1pcs
    Price: negotiation
    Packaging Details: Packed in carton firstly,and then reinforced with wooden case for outer packing
    Delivery Time: 10 working days after received your payment
    Payment Terms: T/T or western Union
    Supply Ability: 3,000pcs per month
    Contact Now
    Detailed Product Description
    Product Name: EKDB 200ARX-300ARX Air Flow Range: 5800 M3/h ~ 9000 M3/h
    Cooling Capacity Range: 56 KW~90 KW Heating Capacity Range: 52 KW~82 KW

    EKDB 200ARX ~ EKDB 300ARX high static pressure duct type total fresh air handling Unit

     

     

    Specifications:

     

     

    Model Indoor unit   EKDB200ARX EKDB250ARX EKDB300ARX
    Outdoor unit   2xEKAA100ARX 2xEKAA125ARX 2xEKAA150ARX
    Rated cooling capacity W 56,000 65,000 90,000
    Rated heating capacity W 52,000 58,000 82,000
    Indoor unit circulating air flow m3/h 5,800 7,000 9,000
    Standard external static pressure Pa 200 200 250
    Power supply   380V/3N~/50Hz
    Indoor unit fan drive mode   V-belt transmission
    Total cooling input power W 20100 24800 33800
    Total heating input power W 19700 24400 31200
    Rated operating current for cooling A 38.2 47.2 64.3
    Rated operating current for heating A 37 46.4 59.3
    Noise Indoor unit dB(A) ≤64 ≤65 ≤65
    Outdoor unit dB(A) ≤65(single unit) ≤65(single unit) ≤68(single unit)
    Outer dimensions (W × D × H) Indoor unit mm 1719x965x736 1719x965x736 2242x1059x735
    Outdoor unit mm 2x990x840x1840 2x990x840x1840 2x1290x840x1840
    Weight Indoor unit kg 188 198 250
    Outdoor unit kg 2x280 2x285 2x300
    Specifications for the condensed water
    drainage pipe
      R1
    Refrigerant type   R22
    Indoor and outdoor unit connection type   Soldering
    Connecting pipe specifications               External diameter of liquid tube mm 2x15.88 2x15.88 2x15.88
    External diameter of air tube                               mm 2x28.6 2x28.6 2x34.9

     

    Note:
    ■ The condition for the cooling capacity is as follows: The air dry bulb reads 34 oC and the wet bulb reads 28 oC. The condition for the
    heating capacity is as follows: The dry bulb reads 7 oC and the wet bulb reads 6 oC. The cooling capacity and heating capacity change
    according to the conditions. During model selection, you need to select a proper model based on local climatic conditions.
    ■ The external static pressure in the preceding table shows the specification for a standard unit. The static pressure changes depending on
    customer requirements. For the specific value, see the reading on the nameplate.
    ■ The unit input power and current are based on the standard external static pressure. If the customer requires a different external static
    pressure, check the nameplate on the unit for the power and current values.
    ■ The noise level is measured before the unit leaves factory. Due to environment noise and other factors in actual operation, the noise level
    may be different from those listed in the preceding table.
    ■ The specifications may suffer change due to product update. The readings on the nameplate of the unit prevail.
    ■ For details about on-site power distribution and wiring for unit installation, see the nameplate or installation manual of the unit.

     

    Description:

     

    1. Intelligence and Fresh Air

     

      The EKDB-X total fresh air Handling system makes fresh air Handling more flexible. A separate fresh air system can directly supply fresh air to indoor in the air supply mode, or to the indoor unit as return air.

     

    2. Long-distance Air Supply

     

        A high external static pressure ensures that air can be supplied to every room over a long distance. The air flow can be as high as 9000 m3/h to meet fresh air requirements in a large area.

     

     

    Competitive Advantage:

     

    The EKDB-X total fresh air Handling system best meets customer requirements for indoor air environment, intelligence, efficiency, and safety. A separate fresh air system can directly supply fresh air to indoor in the air supply mode, or to the indoor unit as return air, making fresh air Handling more flexible. The unit supports flexible combination and intelligent control, meets requirements for indoor space, and provides pleasant and comfortable experience. With its high intelligence and efficiency, low noise, delicate structure, easy operation, safe running, and convenient installation and maintenance, it is widely applicable to commercial scenarios such as hotels, malls, office buildings, and factory workshops.

    High Static Pressure Duct Type Split System Air Conditioning Units 380V 50Hz

     