Home ProductsVRF Air Conditioner

R410A 10KW / 15KW Central VRF Air Conditioner Low Energy Consumption

R410A 10KW / 15KW Central VRF Air Conditioner Low Energy Consumption

    • R410A 10KW / 15KW Central VRF Air Conditioner Low Energy Consumption
    • R410A 10KW / 15KW Central VRF Air Conditioner Low Energy Consumption
    • R410A 10KW / 15KW Central VRF Air Conditioner Low Energy Consumption
  • R410A 10KW / 15KW Central VRF Air Conditioner Low Energy Consumption

    Product Details:

    Place of Origin: China
    Brand Name: EuroKlimat
    Certification: ISO9001, ISO14001, OHSAS18001, CRAA, CQC
    Model Number: EKRV-A

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 pcs
    Price: Negotiation
    Packaging Details: Pallet
    Delivery Time: 20 working days after received your payment
    Payment Terms: L/C, T/T
    Supply Ability: 1500pcs per month
    Contact Now
    Detailed Product Description
    Product Name: Digital Multi-connected Central Air Conditioner Refrigerant: R410A
    Cooling Capacity(kW): 10.0 KW-141.0 KW Heating Capacity(kW): 11.5 KW-152.0 KW
    Unit Minimum DimensionsL×H×W (mm×mm×mm): 970×355×1050 Range Of Sound Level DB(A): 56-65
    Ultra-long Connecting Pipe: Total Pipe Length:1000m Charging Per Customer: Electricity Fee Can Be Calculated In Real Time Based On Customers' Actual Usage.
    Wide Operation Range: Heating Range: -15°C To +29°C; Cooling Range: 0°C To 48°C (standard Model); -5°C To +54°C (with Brushless DC Motors)

     

    EKRV Series Friendly Refrigerant Digital Multi-connected Central Air Conditioner

     

     

    Parameter

     

    Model  

    EKRV040

    A1/ AR1

    EKRV050

    A1/ AR1

    EKRV060

    A1/ AR1

    EKRV050

    A1/ AR1

    EKRV060

    A1/ AR1

    EKRV07

    0A1/ AR1

    Cooling capacity kW 10 12.5 15 12.5 15 19
    Heating capacity* kW 11.5 14 17 15 17.5 21
    Input power Cooling kW 3.3 4.1 4.9 4.1 4.6 5.9
    Heating kW 3 3.8 4.2 3.8 4.2 5.8
    Power supply   220V~/50Hz 220V~/50Hz 220V~/50Hz 380V/3N~/50Hz

    380V/3N~

    /50Hz

    380V/3N~

    /50Hz

    Rated current Cooling A 15.0 18.6 22.3 7.9 8.7 12.2
    Heating A 13.6 17.3 19.1 7.2 8.3 12.0
    Connector size Liquid pipe mm 9.52 9.52 9.52 9.52 9.52 9.52
    Gas pipe mm 15.88 15.88 15.88 15.88 15.88 15.88
    Unit weight kg 120 125 129 125 129 135
    Noise dB(A) 59 59 60 59 60 61
    Refrigerant type   R410A R410A R410A R410A R410A R410A
    Dimensions (W x D x H) mm 970x355x1050 970x355x1255 970x355x1050 970x355x1255

     

     

     

     

     

     

    Model   EKRV080A1/ AR1 EKRV100A1/ AR1 EKRV120A1/ AR1 EKRV140A1/ AR1
    Cooling capacity kW 25 28 33.5 40
    Heating capacity* kW 28 31.5 37 44
    Input power Cooling kW 7 7.8 9.5 11.1
    Heating kW 6.7 7.6 9.2 10.8
    Power supply   380V/3N~/50Hz 380V/3N~/50Hz 380V/3N~/50Hz 380V/3N~/50Hz
    Rated current Cooling A 14.8 16.4 18.3 21.4
    Heating A 13.6 15.1 17.4 20.9
    Connector size Liquid pipe mm 9.52 9.52 12.7 12.7
    Gas pipe mm 22.2 22.2 22.2 28.6
    Unit weight kg 290 300 305 350
    Noise dB(A) 56 57 60 60
    Refrigerant type   R410A R410A R410A  
    Dimensions (W x D x H) mm 990x840x1840 1290x840x1840

     

    Model   EKRV160A1/ AR1 EKRV180A1/ AR1 EKRV200A1/ AR1 EKRV220A1/ AR1 EKRV240A1/ AR1
    Cooling capacity kW 45 50.5 56 61.5 68
    Heating capacity* kW 49.5 56 61 68 73
    Input power Cooling kW 12.9 14.6 15.5 17.3 19.2
    Heating kW 12.5 14 14.6 16.6 18.1
    Power supply   380V/3N~/50Hz 380V/3N~/50Hz 380V/3N~/50Hz 380V/3N~/50Hz 380V/3N~/50Hz
    Rated current Cooling A 24.1 28.7 31.3 34.9 37.3
    Heating A 23.8 27.7 30.8 33.2 35.1
    Connector size Liquid pipe mm 12.7 12.7 15.88 15.88 15.88
    Gas pipe mm 28.6 28.6 28.6 28.6 28.6
    Equalizer pipe size mm -- -- -- -- --
    Unit weight kg 360 370 590 590 600
    Noise dB(A) 60 61 61 62 62
    Refrigerant type   R410A R410A R410A R410A R410A
    Dimensions (W x D x H) mm 1290x840x1840 1990x840x1840

     

    Model   EKRV260A1/ AR1 EKRV280A1/ AR1 EKRV300A1/ AR1 EKRV320A1/ AR1
    Cooling capacity kW 73 78.5 85.0 90.0
    Heating capacity* kW 81.0 86.5 93.5 99.0
    Input power Cooling kW 20.7 22.4 24.0 25.8
    Heating kW 20.1 21.7 23.3 25.0
    Power supply   380V/3N~/50Hz 380V/3N~/50Hz 380V/3N~/50Hz 380V/3N~/50Hz
    Rated current Cooling A 39.7 42.4 46.8 50.3
    Heating A 38.3 42.2 45.3 49.0
    Connector size Liquid pipe mm 15.88 15.88 15.88 19.05
    Gas pipe mm 34.9 34.9 34.9 34.9
    Equalizer pipe size mm 9.52 9.52 9.52 9.52
    Unit weight kg 655 665 710 720
    Noise dB(A) 62 62 62 63
    Refrigerant type   R410A R410A R410A R410A
    Dimensions (W x D x H) mm 2280x840x1840 2580x840x1840

     

    Model   EKRV340 A1/ AR1 EKRV360 A1/ AR1 EKRV380 A1/ AR1 EKRV400 A1/ AR1 EKRV420 A1/ AR1
    Cooling capacity kW 95.5 101.0 108.0 113.0 118.5
    Heating capacity* kW 105.5 112.0 117.0 122.5 129.0
    Input power Cooling kW 27.5 29.2 30.3 32.1 33.8
    Heating kW 26.5 28.0 28.9 30.6 32.1
    Power supply   380V/3N~/50Hz 380V/3N~/50Hz 380V/3N~/50Hz 380V/3N~/50Hz 380V/3N~/50Hz
    Rated current Cooling A 52.8 57.4 58.7 61.5 66.0
    Heating A 52.5 55.4 56.0 59.9 62.8
    Connector size Liquid pipe mm 19.05 19.05 19.05 19.05 19.05
    Gas pipe mm 34.9 34.9 41.3 41.3 41.3
    Equalizer pipe size mm 9.52 9.52 9.52 9.52 9.52
    Unit weight kg 730 740 950 960 970
    Noise dB(A) 63 63 64 64 64
    Refrigerant type   R410A R410A R410A R410A R410A
    Dimensions (W x D x H) mm 2580x840x1840 3280x840x1840

     

    Model   EKRV440 A1/ AR1 EKRV460 A1/ AR1 EKRV480 A1/ AR1 EKRV500 A1/ AR1
    Cooling capacity kW 124.0 129.5 136.0 141.0
    Heating capacity* kW 134.0 141.0 146.0 152.0
    Input power Cooling kW 34.7 36.5 38.4 40.2
    Heating kW 32.7 34.7 36.2 38.1
    Power supply   380V/3N~/50Hz 380V/3N~/50Hz 380V/3N~/50Hz 380V/3N~/50Hz
    Rated current Cooling A 68.6 72.2 74.7 78.2
    Heating A 65.9 68.3 70.2 73.9
    Connector size Liquid pipe mm 19.05 19.05 19.05 19.05
    Gas pipe mm 41.3 41.3 41.3 41.3
    Equalizer pipe size mm 9.52 9.52 9.52 9.52
    Unit weight kg 1190 1190 1200 1200
    Noise dB(A) 65 65 65 65
    Refrigerant type   R410A R410A R410A R410A
    Dimensions (W x D x H) mm 3980x840x1840

     

    Description:

     

    1. Higher Energy Efficiency

    ide Capacity Regulation Range and Precise Ambient Temperature Control

    By using a PWM valve to control the time ratio of unloading and loading status, the digital scroll compressor can continuously regulate the capacity within a range of 10%–100%, increasing the precision of capacity regulation and the stability of indoor temperature.

    Low Energy Consumption

    The unit boasts an outstanding IPLV(C) (refrigerating coefficient of performance). The full series of units features an IPLV(C) that is far higher than national standard energy efficiency level 1.

     

    2. More Advanced Technologies

    Rapid Start Technologies

    EKRV series digital multi-connected central air conditioners can run in full load within a short period, quickly meeting indoor requirements.

     

    Supercooling Technologies

    Enlarges the condenser of the outdoor unit to implement level-1 supercooling, and then uses an efficient supercooler to implement level-2 supercooling, reaching a total supercooling degree of 19.6°C. Enhances the cooling capability of the unit and improves the efficiency of the unit. Reduces the pressure loss when the refrigerant is circulated in the pipe, rationally allocating the ultra-long accessory pipe and refrigerant.

     

    No Electromagnetic Interference

    Without a transducer, EKRV series digital multi-connected central air-conditioning units do not generate high-order harmonic and electromagnetic radiation, providing customers with healthy living and working environment.

     

    Brushless DC motor (optional)

    Fans of outdoor units can be regulated at 32 levels based on load changes, improving efficiency and reducing noise.

    The unit can safely run under light load for a long time.

    Intelligent Defrosting Technologies;

    No Power Consumption Resulting from Power Conversion

     

    3. Wide operation range

    EKRV series digital multi-connected central air-conditioning units can generate cooling result in hot weather with a temperature of 54°C, and generate heating result in cold weather with a temperature of -15°C.

     

    4. Ultra-long Connecting Pipe

    Total pipe length

    1000m

    Max. equivalent length of a single pipe

    220m

    Max. actual length of a single pipe

    175m

    Max. vertical span between outdoor and indoor units

    50m

    Max. vertical span between indoor units

    15m

     

    5. Easy Installation

    The system can provide an external static pressure of 50 Pa, ensuring the heat dissipation result of the outdoor unit under the same installation conditions (optional).

    A higher external static pressure ensures that the outdoor unit can be flexibly installed at a rooftop, compartment, balcony, or equipment floor, preventing overload of the unit due to poor ventilation

     

    6. More Secure

    Dual Backup Operation with Guaranteed Security

    Automatic Fault Diagnosis

    Technologies for Automatic Identification of Pipe Length

    Multiple Measures to Effectively Protect Compressors

    Door Card Function (Optional)

    Intelligent and Balanced Operation Management

     

    7. electronic expansion valve

    The unit uses an electronic expansion valve with 4000-step capacity regulation to increase the precision of superheat degree control (liquid level control), enhance the operation security, and improve energy saving.

     

    8. More Intelligent

    Centralized Monitoring Software

    One set of EKRV centralized monitoring software can control up to 2048 indoor units, meeting customers' requirements for large-scale centralized management.

     

    Separate Control Charging per Customer

    The unit can fairly and rationally divide the electricity quantity based on the model, operation mode, operation time, air supply/ return efficiency, and refrigerant flow of the air conditioning unit to protect the rights and interests of all owners. The unit provides customers with functions such as owner management, price and recharge management, energy saving management.

    Separate Control

    Centralized Control

     

    9. Models of indoor units are diverse for selection.

    Indoor units cover 6 series and 63 capacity types, and total fresh air indoor units are available, fully meeting customer requirements.

     

    10.  More Environment-friendly

    Full Compliance with RoHS Directive,

    Environment-friendly Refrigerant,

    Automatic Refrigerant Recovery Technologies,

    Automatic Determination of Refrigerant Charge,

    Energy Consumption of 5 W in Standby Mode(a Record Low in the Industry)

     

    Applications

     

    hotels,entertainment centers, hospitals, restaurants, office buildings, cinemas,

    factories, school supermarkets and so on.

     

     

    Competitive Advantage:

     

    EKRV unit using R410A refrigerant meets the energy saving and environmental protection.

    Wide operation range. EKRV series digital multi-connected central air-conditioning units can generate cooling result in hot weather with a temperature of 54°C, and generate heating result in cold weather with a temperature of -15°C.

    Models of indoor units are diverse for selection. Indoor units cover 6 series and 63 capacity types, and total fresh air indoor units are available, fully meeting customer requirements.

    Contact Details
    Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd

    Contact Person: LENG

    Send your inquiry directly to us (0 / 3000)

    Other Products