Home ProductsFan Coil Unit

Two pipe 2 Rows Ceiling Air Conditioning Fan Coil Unit ESP 35 pa

Two pipe 2 Rows Ceiling Air Conditioning Fan Coil Unit ESP 35 pa

    • Two pipe 2 Rows Ceiling Air Conditioning Fan Coil Unit  ESP 35 pa
    • Two pipe 2 Rows Ceiling Air Conditioning Fan Coil Unit  ESP 35 pa
  • Two pipe 2 Rows Ceiling Air Conditioning Fan Coil Unit  ESP 35 pa

    Product Details:

    Place of Origin: China
    Brand Name: EuroKlimat
    Certification: ISO9001, ISO14001, OHSAS18001, CRAA, CQC
    Model Number: EKCW-A

    Payment & Shipping Terms:

    Minimum Order Quantity: 1
    Price: negotiation
    Packaging Details: Carton box
    Delivery Time: 10 working days after received your payment
    Payment Terms: L/C, T/T
    Supply Ability: 15,000pcs per month
    Contact Now
    Detailed Product Description
    Product Name: Ceiling Concealed Fan Coil Unit Installation: Ceiling
    Cooling Capacity(kW): 1.14-8.96 Heating Capacity(kW): 3.28-20.77
    Air Flow(m3/h): 279-1952 Aluminum Fins: Shutter-type Hyperbolic And Hydrophilic Fins
    Test Pressure (Mpa): 3.3

     

     

    Two pipe 2 rows ceiling concealed fan coil unit  ESP 35 pa

     

     

    Specifications

     

    Model
    Performance
    EKCW
    200AT
    EKCW
    300AT
    EKCW
    400AT
    EKCW
    500AT
    EKCW
    600AT
    EKCW
    800AT
    EKCW
    1000AT
    EKCW
    1200AT
    EKCW
    1400AT
    Rated air flow (m3/h; under static pressure of 12
    Pa, 30 Pa, and 50 Pa)
    H 340 510 680 850 1020 1360 1700 2040 2380
    M 279 418 558 697 836 1115 1394 1673 1952
    L 170 255 340 425 510 680 850 1020 1190
    Rated cooling capacity (W) Total heating/cooling capacity H 1770 2955 3920 4635 5115 7610 8680 10495 11620
    Sensible heating/cooling capacity H 1140 1980 2570 3205 3735 5535 6680 7765 8955
    Rated heating capacity (W) H 3280 5120 6450 7560 9095 12830 15865 18485 20770
    Rated input power (W) Static pressure of 12 Pa H 32 46 56 73 93 133 164 188 229
    Static pressure of 30 Pa H 39 53 72 86 107 142 183 217 239
    Static pressure of 50 Pa H 46 65 77 90 115 162 187 227 279
    Working current (A) Static pressure of 12 Pa H 0.15 0.21 0.26 0.33 0.42 0.61 0.74 0.85 1.04
    Static pressure of 30 Pa H 0.18 0.24 0.33 0.39 0.48 0.65 0.83 0.99 1.09
    Static pressure of 50 Pa H 0.21 0.29 0.35 0.41 0.52 0.74 0.85 1.03 1.27
    Sound dB(A) Static pressure of 12 Pa H 34.5 34.5 37.5 41.0 45.0 44.5 48.0 49.0 52.0
    Static pressure of 30 Pa H 37.0 40.0 42.5 44.0 45.5 46.5 49.5 49.5 53.0
    Static pressure of 50 Pa H 41.0 43.0 45.0 46.0 47.5 48.0 50.0 51.0 53.5
    Water flow (m3/h) 0.32 0.51 0.67 0.80 0.88 1.31 1.47 1.81 2.01
    Water resistance (cooling) (kPa) 5 14 26 36 18 40 28 40 34
    Water resistance (heating) (kPa) 4 12 21 30 14 34 23 34 28
    Coil Type Mechanically expanded quality copper tubes specially designed for air conditioners with shutter-type hyperbolic aluminum fins
    Working pressure 1.6MPa
    Test pressure Airtightness test under pressurized water: 3.3 MPa
    Fan Type Forward-pitched multi-wing centrifugal fan with double-suction impellers made from zinc-plated steel plates
    Qty. 1 2 2 2 2 3 4 4 4
    Motor Type Single-phase  ball-bearing capacitive motor with a high precision and low operation sound
    Qty. 1 1 1 1 1 2 2 2 2
    Power supply 220V~/50Hz
    Protection grade IP20
    Insulation grade B
    Inlet/outlet water pipe Pipe diameter Rc3/4 taper pipe with internal thread
    Condensate water pipe Pipe diameter Diameter R 3/4 taper pipe with external threads
    Net weight (no electric heater) No return air plenum kg 10.4 12.3 14.6 15.4 16.2 24.4 27.1 29.4 35.5
    With return air plenum kg 13.4 15.9 18.6 19.7 20.8 30.4 33.5 36.6 43.7
    Electric heater
    (optional)
    Power supply   220V~/50Hz 380V/3N~/50Hz
    Electric heating capacity kW 1.0/2.0

    1.0/2.0

    /3.0

    2.0/3.0

    /4.0

    2.0/3.0

    /4.0

    2.0/3.0

    /4.0

    3.0/4.0

    /5.0

    3.0/4.0

    /5.0

    4.0/5.0

    /6.0

    5.0/6.0

    /7.0

    Net weight (with electric heater) No return air plenum kg 13.5 15.6 18.3 19.3 20.4 29.5 32.4 35.2 42.0
    With return air plenum kg 16.5 19.2 22.3 23.6 25.0 35.5 38.8 42.4 50.2

     

    Note:
    ■ Working conditions for cooling: inlet air temperature - dry/wet bulb 27°C/19.5°C; temperature of inlet/outlet water - 7°C/12 °C.
    ■ Working conditions for heating: inlet air temperature - dry bulb 21°C; inlet water temperature 60°C; water flow - equal to that for cooling
    operation.
    ■ Rated air flow is measured under standard atmosphere using dry coils (dry bulb 20°C).
    ■ Sound pressure grade and sound level are measured in a semi-silent room as per GB/T 19232-2003.
    ■ H, M and L represent high, medium and low fan speed respectively.
    ■ Static pressure refers to outlet static pressure.
    ■ All performance parameters in the above table are measure with a power supply of 220V~/50Hz.
    ■ The right/left orientation of connection pipes are exchangeable on site (cooling/heating capacity needs to be multiplied by a correction factor
    of 0.93 after exchange).

     

     

    1.Compact Exterior

     

    With a compact, graceful and robust design, this
    super-thin unit can be concealed in a small space
    inside the ceiling.

     

    2.Low Noise


    The unit features a forward-pitched low-speed centrifugal fan with wide impellers. The fan has a good
    dynamic balance and a stable performance, and minimizes the operation sound while ensuring enough air
    flow and the static pressure of outlet air by using efficient sound-dampening and heat-insulation material.

     

    3.Efficient and Energy Saving
     

    To maximize heat transfer and exchange efficiency, the unit features heat exchange coils made of quality
    copper tubes, efficient hyperbolic aluminum shutter fins, precise mechanic tube expansion and a fan with
    wide impellers and a high air supply capacity.

     

    4.Easy and Flexible Installation
     

    The unit features a symmetric design and can be easily installed. The left and right connection pipes are
    exchangeable. For units with a return air plenum, the air return mode can be customized.

     

    5.Safe and Leakage-proof
     

    The condensate water collector are molded as a whole (no welding line or dots) and entirely coated with
    fireproof material to prevent leakage. A specially designed pitch on the collector also helps ensure smooth
    discharge of condensate water.

     

    6.Easy Maintenance


    The unit features a single-phase capacitive motor with a low operation sound and a long service life thanks
    to a quality precision ball bear that is hermetic, fully lubricated, rustproof and durable. All wires leading out of
    the motor are protected against damage using flexible metal tubes.

     

    Contact Details
    Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd

    Contact Person: LENG

    Send your inquiry directly to us (0 / 3000)